How to install Windows Server 2008 R2 on Dell R720 server

How to install Windows Server 2008 R2 on Dell R720 server

Note: All pictures in this article are collected from the Internet, so they may not be the installation interface of the DELL R720 server, but the interface content can be guaranteed to be close to the installation interface of the DELL R720

1. Preparation items before installation

DELL R720 server and related hardware

DELL Systems Management Tools and Documentation CD

Windows Server 2008 R2 genuine installation disk

2. Configure Server RAID

1. On the power-on self-test interface, follow the on-screen prompts and press Ctrl+R to enter the RAID configuration interface, as shown in Figure 2-1:

Figure 2-1 Power-on self-test interface

2. After a short wait, the system automatically enters the Virtual Disk Management window and is ready to start configuring RAID, as shown in Figure 2-2:

Note: In this interface, press Ctrl+N and Ctrl+P to switch interfaces.

Figure 2-2 Virtual Disk Manager Interface

3. At this time, the virtual disk is empty. Press the up and down keys to keep the cursor on the row where the array card model is located (PERC H310 Mini in the figure). Press F2 to pop up the menu and select Create New VD to create a new virtual disk, as shown in Figure 2-3:

Figure 2-3 Create Virtual Disk menu item

4. Press Enter in the RAID Level option and the supported RAID levels will appear. The RAID card can support RAID0/1/5/10/50. Depending on the number of hard disks, the options that appear here may also be different. Selecting different levels will give you different options. Here we select RAID1 and press Enter to confirm. As shown in Figure 2-4:

Figure 2-4 RAID Level menu

5. After confirming the RAID level, press the down arrow key to move the cursor to the Physical Disks list, move up or down to the hard disk position you want to select, and press the space bar to select the hard disk in the list. When the number of selected hard disks reaches the requirements of the RAID level set in the previous step, the default capacity information of this RAID can be displayed in VD Size of Basic Settings. The hard disk with an X mark is selected.

After selecting the hard disk, press the Tab key to move the cursor to the VD Size column. The VD Size can be set manually, which means that not all capacity needs to be configured in one virtual disk. If this virtual disk does not use all the capacity of the RAID array we configured, the remaining space can be configured as another virtual disk, but you must return to VD Mgmt to create the next virtual disk. VD Name can be set as needed or left blank. As shown in Figure 2-5:

Note: The minimum number of hard disks required for each RAID level is: RAID0=1 RAID1=2 RAID5=3 RAID10=4 RAID50=6

Figure 2-5 RAID configuration

6. Regarding Advanced Settings, it is not recommended to change them unless there is a special requirement.

7. After the above configuration is confirmed, press the Tab key, move the cursor to OK, and press Enter. The following prompt will appear. If it is a brand new array, it is recommended to initialize it. If the purpose of configuring the array is to restore previous data, do not initialize it. Press Enter to confirm and continue.

Figure 2-6 Configuration confirmation interface

8. After the configuration is completed, you will return to the Virtual Disk Manager page, as shown in Figure 2-7:

Figure 2-7 The virtual disk manager interface after configuration is completed

9. Use the up and down arrow keys to move the cursor to the newly created virtual disk, and press F2 to pop up the menu. You can initialize (Initialization), consistency check (Consistency Check), delete (Delete), view properties, and other operations on the virtual disk (Virtual Disk 0) that has just been successfully configured. Here we perform initialization operations. As shown in Figure 2-8:

Figure 2-8 Initializing the virtual disk

10. After selecting the initialization operation, a confirmation prompt box will pop up. If you confirm the initialization operation, press Enter at OK to continue, as shown in Figure 2-9:

Figure 2-10 Confirm initialization

11. Wait for the disk to initialize. Once completed, the virtual disk configuration is complete.

3. Configure server hot standby

There are two modes for configuring hot spare. One is global hot spare, which means that the hot spare hard disk can be used as a hot spare for all arrays on this channel. The other is independent hot spare, which configures the hard disk as a hot spare for all virtual disks in a specified disk group. In other words, even if the hard disks of other arrays outside this disk group are offline, the hot spare will not automatically rebuild the data.

1. Configure global hot standby

Assume that we have already prepared RAID for the hard disk as shown in Figure 3-1.

Figure 3-1 Completed RAID

1) Press Ctrl+N to switch to the PD Mgnt interface, where you can see the status of the hard disk, as shown in Figure 3-2:

Figure 3-2 Hard disk status

2) You can see that the status of the hard disk configured with RAID is Online, while the status of the unconfigured hard disk is Ready. Move the cursor to the physical disk you want to configure as a hot spare disk (the hard disk status must be Ready), press F2 to pop up the menu, and select Make Global HS.

Figure 3-3 Selecting hot standby items

3) After confirming the selection, the status of the hard disk just selected changes to Hotspare, and the hot spare disk configuration is completed. Return to VD Mgnt, and you can see that the hot spare disks of the two RAIDs are the same hard disk. The global hot standby configuration is complete.

Figure 3-4 Global hot spare disk configuration completed

2. Configure independent hot standby

1) Assume that we have already made two RAID arrays, RAID1 and RAID10. We hope to set the free hard disk ID = 06 as a hot spare hard disk dedicated to the RAID10 array. In this way, when a hard disk failure occurs in the RAID10 array, the hot spare hard disk automatically rebuilds the data and is added to the RAID10 array. As shown in Figure 3-5:

Figure 3-5 RAID configuration diagram

2) Press the up and down arrow keys to highlight the RAID10 group (Spanned Disk Group:0), press F2, and select Manage Ded. HS in the pop-up menu. As shown in Figure 3-6:

Figure 3-6 Selecting an independent hard disk

3) In the pop-up menu, select the hard disk you want to use as a hot spare disk and press the space bar to select it, as shown in Figure 3-7:

Figure 3-7 Selecting an independent hot spare disk

4) After confirming and clicking OK, return to the VD Mgnt interface, and you can see that the independent hot spare disk setting of RAID10 is complete, as shown in Figure 3-8:

Figure 3-8 Independent hot spare disk settings completed

4. Boot using the system boot disk

1. Place the Systems Management Tools and Documentation CD-ROM that comes with the server into the server CD-ROM drive, set the server to boot from the CD-ROM drive, and then boot the CD-ROM, as shown in Figure 4-1.

Figure 4-1 Boot CD interface

2. Wait for the boot disk to detect the server hardware. It takes about 5 minutes. Please wait patiently, as shown in Figure 4-2:

Figure 4-2 Waiting for hardware detection

3. Select the language. This needs no introduction. . . . . . . .

Figure 4-3 Select language

4. Accept the agreement. If you do not accept, you cannot proceed to the next step. Select Accept.

5. The installation screen appears, click "Server OS Installation"

Figure 4-4 Server operating system installation

6. After clicking Configure, the left sidebar of the screen is displayed as shown in Figure 4-5. The number of items here may not necessarily be seven, depending on the situation.

Figure 4-5 Left sidebar

7. Step 1: Please set the time zone to: Beijing, Hong Kong, Chongqing, Urumqi

8. Step 2: Select the operating system you want to install and pay attention to the prompts at the bottom of the screen.

9. Step 3: Confirm the RAID configuration and choose to keep the system RAID configuration.

Figure 4-6 RAID configuration

10. The next few steps may not appear. If they do not appear, save the configuration. When the CD-ROM drive pops up and the screen prompts you to insert the system disk, insert the system disk. If it appears, configure according to the system prompts. In general, keep the default configuration. At this point, the system boot is complete, and you can then install the server operating system.

<<:  How much data can be stored in a MySQL table?

>>:  CSS modular solution

Recommend

How to implement the observer pattern in JavaScript

Table of contents Overview Application scenarios ...

How to use VirtualBox to build a local virtual machine environment on Mac

1. Big Data and Hadoop To study and learn about b...

Detailed explanation of the role of explain in MySQL

1. MYSQL index Index: A data structure that helps...

Perfect Solution for No rc.local File in Linux

Newer Linux distributions no longer have the rc.l...

JavaScript counts the number of times a character appears

This article example shares the specific code of ...

Vue ElementUI implements asynchronous loading tree

This article example shares the specific code of ...

Detailed explanation of the usage and differences of MySQL views and indexes

MySQL Views Simply put, a MySQL view is a shortcu...

Solve the problem of PhPStudy MySQL startup failure under Windows system

Report an error The Apache\Nginx service started ...

Windows 10 1903 error 0xc0000135 solution [recommended]

Windows 10 1903 is the latest version of the Wind...

How to implement element floating and clear floating with CSS

Basic Introduction to Floating In the standard do...

The difference between clientWidth, offsetWidth, scrollWidth in JavaScript

1. Concept They are all attributes of Element, in...

Several skills you must know when making web pages

1. z-index is invalid in IE6. In CSS, the z-index...

A brief discussion on whether CSS animation will be blocked by JS

The animation part of CSS will be blocked by JS, ...